ict shielded cervicom lshf cpr

Shielded telephone cable in distribution installations for subscribers inside buildings (According to RD 401/2003 of cables for ICT)

See only CPR
See by cable type
See by fire behaviour

If you need technical support complete the form or call us at (+34) 937 362 730

Support
ICT - Shielded Cervicom LSHF CPR
~\ImgCli\FOTO2_836.jpg
Shielded telephone cable in distribution installations for subscribers inside buildings (According to RD 401/2003 of cables for ICT)
Protegido electromagneticas
No propagador de la llama
No propagador incendio
Libre halogenos
Humos baja opacidad
Baka corrosividad gases
Construction
1. Conductor
Bare copper wire
Diameter: 0,51mm
2. Insulation
High density solid polyethylene
3. Composition
Twisted pairs
4. Assembly
Up to 26 pairs in concentric layers
> 25 pairs with identification thread
Wrapping: Polyester tape
5. Overall screen
Aluminium/polyester tape with continuity thread
6. Outer sheath
Halogen free compound. Colour: Grey
Technical characteristics
1. Conductor resistance
91 Ohm/Km Max.
2. Resistance unbalance
Maximum Value: 2.5%
3. Insulation resistance
Min. 5000 MOhm*Km (500V, 15°C)
4. Mutual capacitance
Medium value max.: 55 nF/km
Maximum value: 58 nF/km
5. Capacitance unbalance
Max.Value pair-pair: 260 pF/km
Max.Value pair-ground: 2625 pF/km
6. Dielectric strength
Cond-Cond: 1000 V
Cond-Screen: 2500 V
7. Nominal attenuation (dB/100m)
0.8 kHz: 1.30 dB/km
3k kHz: 2.52 dB/km
150k kHz: 8.3 dB/km
1000k kHz: 21.4 dB/km
8. Operating Tª
Operation: -25°C to +75°C
9. Min. bending radius
12xD
Standards
1. Ref. for construction/drawing
ICT RD 401/2003
2. CPR Classification (Euroclass)
Dca-s2, d2, a1 (According to UNE-EN 50575)
3. Flame Retardant
UNE-EN 60332-1 (IEC 60332-1)
4. Fire Retardant
EN 50399
5. Halogen free
UNE-EN 60754-1 (IEC 60754-1)
6. Low smoke emission
UNE-EN 61034 (IEC 61034)