Cable Cervicom FIBRE CERH DAHR LSHF CPR

Universal fiber optic cable, suitable for indoor/outdoor installations. Specially recommended when a zero halogen emission in case of fire is required. The internal fiberglass reinforcement (dielectric armor) provides the cable with a certain resistance against the action of rodents.

See only CPR
See by cable type
See by fire behaviour

If you need technical support complete the form or call us at (+34) 937 362 730

Support
Cable Cervicom FIBRE CERH DAHR LSHF CPR
~\ImgCli\FOTO2_223.jpg
Universal fiber optic cable, suitable for indoor/outdoor installations. Specially recommended when a zero halogen emission in case of fire is required. The internal fiberglass reinforcement (dielectric armor) provides the cable with a certain resistance against the action of rodents.
No propagador de la llama
Libre halogenos
Humos baja opacidad
Baka corrosividad gases
Resistente UV
Construction
1. Nº Fibres
4/6/8/12/16/24
2. Identification
See attached colour table
3. Composition
Gel-filled Loose Tube
4. Strength members
Fiberglass reinforcement.
Waterblocking fibers or eventually, water resistant longitudinal tape under the fiberglass.
5. Outer sheath
Special halogen free compound (UV)
(Ricord under the outer sheath)
colour: Black
Technical characteristics
1. Outer diameter
< 8,5mm
2. Weight
< 75 Kg/Km
3. Max. Tensile Load
Permanent: 600 N
During installation and handling: 1800 N
4. Max. Crush
1500 N/dm
5. Operating Tª
Operation: -30°C + 70°C
6. Min. bending radius
Operation: 15xD
During installation: 20xD
Standards
1. Reference standards
EN 50173, ISO/IEC 11801, IEC 60794-1
2. CPR Classification (Euroclass)
Dca-s2,d2,a1
(According to UNE-EN 50575)
*NOTE: This information (CPR classification) may change for older stock. Therefore, in case of order it must be confirmed against the existing stock at that time.
3. Flame Retardant
UNE-EN 60332-1 (IEC 60332-1)
4. Halogen free
UNE-EN 60754-1 (IEC 60754-1)
5. Low smoke emission
UNE-EN 61034 (IEC 61034)