Cable Cervicom DeviceNet Thin

Flexible cable for fixed installations of industrial processes with Device Net BUS networks (Thin cable). With separate pairs for data and power transmission.

See only CPR
See by cable type
See by fire behaviour

If you need technical support complete the form or call us at (+34) 937 362 730

Support
Cable Cervicom DeviceNet Thin
~\ImgCli\FOTO2_935.jpg
Flexible cable for fixed installations of industrial processes with Device Net BUS networks (Thin cable). With separate pairs for data and power transmission.
Protegido electromagneticas
No propagador de la llama
Hidrocarburos
Flexible
Desina
Resistente aceites
Construction
1. Conductor
Flexible tinned copper wires
Gauge: AWG24
2. Insulation
Foamed polyolefin
Identification: White, Blue
3. Individual screen
Aluminium/polyester tape over each pair
4. Assembly
2xAWG24 shielded + 2xAWG22 shielded laid up together + tinned copper drain wire
5. Overall screen
Tinned copper wires braid
Coverage: 80% Min.
6. Outer sheath
PVC (Polyvinyl chloride)
Colour: Violet (Similar to RAL 4001)
Technical characteristics
1. Conductor resistance
92 Ohm/Km Max. (AWG24) / 59 Ohm/Km Max. (AWG22)
2. Insulation resistance
200 MOhm*Km Min.
3. Test Voltage
500 V
4. Operating voltage
30 V
5. Nominal capacitance
46 pF/m
6. Characteristic Impedance
120 Ohm Nom.
7. Operating Tª (conductor)
-20°C +90°C
8. Min. bending radius
5xD
Standards
1. Reference standards
UL File No: E83517
UL/CSA - UR (UL Recognised Component):AWM Style 2637
2. Flame Retardant
EN 50265-1-2 ; IEC 60332-1-2 ; UL VW-1 ; CSA FT1
3. Oil and hydrocarbon resistant
UL 1581 ; VDE 472 part 803 A/B