cable cervicom eapsp multicore 14mm cpr

Multi-core cable for railway infrastructures, used as signalling cables. Installation in a gutter or directly buried (cover with special protection against rodents).

See only CPR
See by cable type
See by fire behaviour

If you need technical support complete the form or call us at (+34) 937 362 730

Support
Cable Cervicom EAPSP Multicore 1,4mm CPR
~\ImgCli\FOTO2_283.jpg
Multi-core cable for railway infrastructures, used as signalling cables. Installation in a gutter or directly buried (cover with special protection against rodents).
Protegido electromagneticas
Anti roedores
Resistente agua
Enterrado directo
Construction
1. Conductor
Bare copper wire
Diameter: 1,4mm
2. Insulation
Solid polyethylene
3. Individual assembly
Insulated conductors
Identification: Colour code acc. to Adif (See attached table)
4. Assembly
In concentric layers
Enclosure: Dielectric tape longitudinally aplied and overlapped
5. Overall screen
Copolymer coated aluminium tape, longitudinal, overlapped and adhered to the inner PE cover
6. Inner sheath
Polyethylene
Colour standard: Black
7. Armour
Copolymer-coated corrugated steel tape, logitudinally applied and overlapped
8. Outer sheath
Polyethylene (UV Resistant)
Colour standard: Black
Technical characteristics
1. Conductor resistance
Maximum Value: 11,9 Ohm/Km
2. Insulation resistance
Min. 35000 MOhm*Km (500V, 15°C)
3. Dielectric strength
Cond-Cond: 3000 V
Cond-Screen: 5000 V
4. Operating Tª (conductor)
Operaction: -25°C to +75°C
5. Min. bending radius
15xD
Standards
1. Ref. standard for drawing
ADIF ET-03.365.052.4
2. CPR Classification (Euroclass)
Fca