ICT Shielded Cervicom LSHF CPR

Multi-pair shielded telephone cable for distribution and dispersion networks for subscribers according to Real Decreto 401/2003 on ICT cables. Suitable for indoor installations where no halogen emission in case of fire is required

See only CPR
See by cable type
See by fire behaviour

If you need technical support complete the form or call us at (+34) 937 362 730

Support
ICT - Shielded Cervicom LSHF CPR
~\ImgCli\FOTO2_836.jpg
Multi-pair shielded telephone cable for distribution and dispersion networks for subscribers according to Real Decreto 401/2003 on ICT cables. Suitable for indoor installations where no halogen emission in case of fire is required
Protegido electromagneticas
No propagador de la llama
Libre halogenos
Humos baja opacidad
Baka corrosividad gases
Construction
1. Conductor
Bare copper wire
Nominal diameter: 0,5mm
2. Insulation
PE (solid polyethylene)
Identification: Colour code
3. Composition
Twisted pairs laid up together
4. Overall screen
Aluminium/polyester tape + drain wire
Coverage: 100%
5. Outer sheath
Halogen free compound
Colour: Grey
Technical characteristics
1. Conductor resistance
98 Ohm/Km Max.
2. Resistance unbalance
2,5% Max.
3. Insulation resistance
5000 MOhm*Km Min. (500V, 20°C)
4. Mutual capacitance
55 nF/km Medium Max.
58 nF/km Max.
5. Capacitance unbalance
Max. value pair-pair: 260 pF/km (Max. individual)
6. Dielectric strength
Cond-Cond: 500 V
Cond-Screen: 1500 V
7. Attenuation (dB/Km)
1,30 dB/km at 800 Hz
2,52 dB/km at 3 kHz
8,3 dB/km at 150 kHz
21,4 dB/km at 1 MHz
8. Operating Tª (conductor)
-15°C to +70°C
9. Min. bending radius
10xD
Standards / Properties
1. Reference standards
ICT Real Decreto 346/2011
2. CPR Classification (Euroclass)
Dca-s2,d2,a2
(According to UNE-EN 50575)
3. Flame Retardant
UNE-EN 60332-1 (IEC 60332-1)
4. Halogen free
UNE-EN 60754-1 (IEC 60754-1)
5. Low smoke emission
UNE-EN 61034 (IEC 61034)