cat 6 cable cervicom data uftp pvc cpr

Shielded Category 6 data transmission cable for local area networks (LAN) in fixed installations, both dry and wet.

See only CPR
See by cable type
See by fire behaviour

If you need technical support complete the form or call us at (+34) 937 362 730

Support
Cat. 6 - Cable Cervicom DATA U/FTP PVC CPR
~\ImgCli\FOTO2_1308.jpg
Shielded Category 6 data transmission cable for local area networks (LAN) in fixed installations, both dry and wet.
Protegido electromagneticas
No propagador de la llama
Construction
1. Conductor
Bare copper wire
Diameter: 0,56 mm (AWG 23)
2. Insulation
FoamSkin PE (Foam polyethylene)
Diameter: 1,35 mm
3. Composition
Two insulated conductors twisted together as a pair
4. Pair Screen
Aluminium/Polyester tape in "S" shape helically applied on two pairs covering each of them individually
5. Assembly
4 shielded pairs laid up together
6. Overall screen
-
7. Outer sheath
PVC
Colour: Blue (RAL 5012)
Technical characteristics
1. Outer diameter
6,5 mm
2. Weight
41 Kg/Km
3. Operating Tª
Fixed installation: -20°C to +60°C
During installation: 0°C to +50°C
4. Min. bending radius
Fixed installation (without load): 4xD
During installation (with load): 8xD
5. Loop resistance
154 Ohm/Km Max.
6. Resistance unbalance
2% Max.
7. Insulation resistance
2000 MOhm*Km Min. (500V)
8. Mutual capacitance
Nominal 43 pF/m (at 800Hz)
9. Capacitance unbalance
1500 pF/Km Max. (Pair-Ground)
10. Characteristic Impedance
100 ± 5 Ohm (at 100 MHz)
11. Velocity of propagation
79%
12. Propagation delay
Nominal 427 ns/100m
13. Test Voltage
1000 V (DC, 1 min)
14. Transfer Impedance
Max. 50 mOhm/m (at 1 MHz)
Max. 100 mOhm/m (at 10 MHz)
Max. 200 mOhm/m (at 30 MHz)
15. Coupling attenuation
55 dB
16. Segregation class
"c"
Standards / Properties
1. Ref. standard for drawing
TIA/EIA-568-C.2
ISO/IEC 11801; IEC 61156-5
EN 50173; EN 50288-6-1
IEEE 802.3at
2. CPR Classification (Euroclass)
Eca
(According to UNE-EN 50575)
3. Flame Retardant
UNE-EN 603332-1 (IEC 60332-1)