cat 5e cable cervicom data futp pe outdoors

Shielded Category 5e data transmission cable for local area networks (LAN) in outdoor fixed installations.

See only CPR
See by cable type
See by fire behaviour

If you need technical support complete the form or call us at (+34) 937 362 730

Support
Cat. 5e - Cable Cervicom DATA F/UTP PE (Outdoors)
~\ImgCli\FOTO2_1262.jpg
Shielded Category 5e data transmission cable for local area networks (LAN) in outdoor fixed installations.
Protegido electromagneticas
Resistente UV
Construction
1. Conductor
Bare copper wire
Diameter: 0,51 mm (AWG24)
2. Insulation
Polyethylene
Diameter: 1,0 mm
3. Composition
Two insulated conductors twisted together as a pair
4. Individual screen
-
5. Assembly
4 twisted pairs laid up together
6. Overall screen
Aluminium/polyester + tinned copper drain wire (AWG26)
7. Outer sheath
PE (Polyethylene)
Standard colour: Black
Technical characteristics
1. Outer diameter
6,2 mm
2. Weight
34 Kg/Km
3. Operating Tª (conductor)
Fixed installation: -20°C to +60°C
During installation: 0°C to +50°C
4. Min. bending radius
Fixed installation (without load): 25mm Min.
During installation (with load): 50mm Min.
5. Loop resistance
190 Ohm/Km Max.
6. Resistance unbalance
2% Max.
7. Insulation resistance
2000 MOhm*Km Min. (500V)
8. Mutual capacitance
Nominal 48 pF/m (at 800Hz)
9. Capacitance unbalance
1500 pF/Km Max. (Pair-Ground)
10. Characteristic Impedance
100 ±5 Ohm
11. Velocity of propagation
67%
12. Propagation delay
1000 V (DC, 1 min)
13. Test Voltage
1000 V (DC, 1 min)
14. Transfer Impedance
Max. 50 mOhm/m (at 1 MHz)
Max. 100 mOhm/m (at 10 MHz)
Max. 200 mOhm/m (a 30 MHz)
15. Coupling attenuation
55 dB Min.
16. Segregation class
-
Standards / Properties
1. Standards
ISO/IEC 11801; IEC 61156-5
EN 50173; EN 50288-2-1
TIA 5682-1