Construction
1. Conductor
Stranded Bare copper wires
Diameter: 0,48 mm (AWG26/7)
2. Insulation
Polyethylene
Diameter: 0,95 mm
3. Composition
4 twisted pairs laid up together
4. Overall screen
Aluminium/polyester tape + tinned copper drain wire (AWG26)
5. Outer sheath
Halogen free compound
Standard colour: Grey (RAL 7035)
Technical characteristics
1. Outer diameter
5,4 mm
2. Weight
25 Kg/Km
3. Operating Tª
Fixed installation: -20°C to +60°C / During installation: 0°C to +50°C
4. Min. bending radius
Fixed installation (without load): 20mm / During installation (with load): 40mm
5. Loop resistance
260 Ohm/Km Max.
6. Resistance unbalance
3% Max.
7. Insulation resistance
5000 MOhm*Km Min. (500V)
8. Mutual capacitance
Nominal 48 pF/m (at 800Hz)
9. Capacitance unbalance
1200 pF/Km Max. (Pair-Ground)
10. Characteristic Impedance
100 ± 5 Ohm (at 100 MHz)
11. Velocity of propagation
67%
12. Propagation delay
Nominal 535 ns/100m
13. Test Voltage
1000 V (DC, 1 min)
14. Transfer Impedance
-
15. Coupling attenuation
55 dB Min.
16. Segregation class
50 mOhm/m Max. at 1MHz / 100 mOhm/m Max. at 10MHz / 200 mOhm/m Max. at 30MHz
Standards / Properties
1. Ref. standard for drawing
TIA/EIA 568-B.2; ISO/IEC 11801; IEC 61156-6; EN 50173-1; EN 50288-2-2
2. Flame Retardant
UNE-EN 60332-1 (IEC 60332-1)
3. Halogen free
UNE-EN 60754 (IEC 60754)
4. Low smoke emission
UNE-EN 61034 (IEC 61034)
5. CPR Classification (Euroclass)
Eca (According to UNE-EN 50575)