cat 5e cable cervicom data uutp lshf patch flexible cpr

Category 5e flexible halogen free cable for local area networks (LAN), suitable for work area (computers) and panel cabling.

See only CPR
See by cable type
See by fire behaviour

If you need technical support complete the form or call us at (+34) 937 362 730

Support
Cat. 5e - Cable Cervicom DATA U/UTP LSHF PATCH (Flexible) CPR
~\ImgCli\FOTO2_1256.jpg
Category 5e flexible halogen free cable for local area networks (LAN), suitable for work area (computers) and panel cabling.
No propagador de la llama
Libre halogenos
Humos baja opacidad
Flexible
Baka corrosividad gases
Construction
1. Conductor
Stranded Bare copper wires
Diameter: 0,48 mm (AWG26/7)
2. Insulation
Polyethylene
Diameter: 0,90 mm
3. Composition
Two insulated conductors twisted together as a pair
4. Assembly
4 twisted pairs laid up together
5. Outer sheath
Halogen free compound
Standard colour: Grey (RAL 7035)
Technical characteristics
1. Outer diameter
5,2 mm
2. Weight
25 Kg/Km
3. Operating Tª
Fixed installation: -20°C to +60°C / During installation: 0°C to +50°C
4. Min. bending radius
Fixed installation (without load): 4xD / During installation (with load): 8xD
5. Loop resistance
260 Ohm/Km Max.
6. Resistance unbalance
3% Max.
7. Insulation resistance
2000 MOhm*Km Min. (500V)
8. Mutual capacitance
Nominal 48 pF/m (at 800Hz)
9. Capacitance unbalance
1500 pF/Km Max. (Pair-Ground)
10. Characteristic Impedance
100 ± 5 Ohm (at 100 MHz)
11. Velocity of propagation
67%
12. Propagation delay
Nominal 535 ns/100m
13. Test Voltage
1000 V (DC, 1 min)
14. Transfer Impedance
-
15. Coupling attenuation
40 dB Min.
16. Segregation class
-
Standards / Properties
1. Ref. standard for drawing
TIA/EIA 568A; ISO/IEC 11801 Ed.2; IEC 61156-6; EN 50173-1; EN 50288-3-2
2. Flame Retardant
UNE-EN 60332-1 (IEC 60332-1)
3. Halogen free
UNE-EN 60754 (IEC 60754)
4. Low smoke emission
UNE-EN 61034 (IEC 61034)
5. CPR Classification (Euroclass)
Eca (According to UNE-EN 50575)