Construction
1. Conductor
Bare copper wire
Diameter: 0,60mm
2. Insulation
PE (Solid polyethylene)
Identification:
· 1 pair: White, Brown
· 2 pairs: White-Brown, Red-Green
3. Composition
Twisted pairs
*Two pair cable is laid up as a star quad
4. Inner sheath
PVC (Polyvinyl chloride)
Colour: Black
5. Armour
Galvanised steel wire braid
6. Outer sheath
PVC (Polyvinyl chloride)
Colour: Black
Technical characteristics
1. Conductor resistance
65 Ohm/Km Max.
2. Resistance unbalance
Max. value: 2%
3. Insulation resistance
8000 MOhm*Km
4. Mutual capacitance
58 nF/km Max.
5. Dielectric strength
Cond-Cond: 1500 V
6. Nominal attenuation (dB/100m)
0.8 kHz: 1.20 dB/km
1.5 kHz: 1.70 dB/km
3.0 kHz: 2.30 dB/km
40 kHz: 4.5 dB/km
96 kHz: 6.0 dB/km
1000 kHz: 21 dB/km
10000 kHz: 66 dB/km
40000 kHz: 137 dB/km
7. Operating Tª (conductor)
-5°C to +70°C
8. Min. bending radius
12xD
Standards
1. Reference standards
ICT Real Decreto 346/2011
2. Flame Retardant
UNE-EN 60332-1 (IEC 60332-1)
3. CPR Classification (Euroclass)
Eca
(According to UNE-EN 50575)