Cat 6 Cable Cervicom DATA UUTP Cat6 LSHF PATCH Flexible CPR

Flexible halogen-free Category 6 patch cable for use in local area networks (LAN) in the work area and panel cabling (not recommended for fixed installation). For Telephone Systems, Ethernet, Fast Ethernet and Gigabit Ethernet applications, 10BaseT, 100BaseT, 1000BaseT, 1GBase-T up to 1,000 Mbit/s, ISDN; TPDDI applications. Suitable for PoE and

See only CPR
See by cable type
See by fire behaviour

If you need technical support complete the form or call us at (+34) 937 362 730

Support
Cat. 6 - Cable Cervicom DATA U/UTP Cat.6 LSHF PATCH (Flexible) CPR
~\ImgCli\no-foto.jpg
Flexible halogen-free Category 6 patch cable for use in local area networks (LAN) in the work area and panel cabling (not recommended for fixed installation). For Telephone Systems, Ethernet, Fast Ethernet and Gigabit Ethernet applications, 10BaseT, 100BaseT, 1000BaseT, 1GBase-T up to 1,000 Mbit/s, ISDN; TPDDI applications. Suitable for PoE and PoE+ on a channel length of up to 60 m.
No propagador de la llama
Libre halogenos
Humos baja opacidad
Flexible
Baka corrosividad gases
Construction
1. Conductor
Flexible bare copper wires
Gauge: AWG26
2. Insulation
Polyethylene
Diameter: 1 mm Approx.
3. Composition
Twisted pairs
4. Outer sheath
Halogen free compound
Colour: Grey
Technical characteristics
1. Operating Tª (conductor)
Fixed installation: -20°C a +60°C
During installation: 0°C a +50°C
2. Min. bending radius
Fixed installation (without load): 4xD
During installation: 10xD
3. Loop resistance
340 Ohm/Km Max.
4. Insulation resistance
5000 MOhm*Km Min.
5. Mutual capacitance
48 pF/m Nominal
6. Characteristic Impedance
100 Ohm Nominal
7. Velocity of propagation
79%
8. Propagation delay
427 ns/100m Max.
9. Test Voltage
1000 V
10. Transfer Impedance
-
11. Coupling attenuation
40 dB
12. Segregation class
C (EN 50174-2)
Standards / Properties
1. Reference standards
EN50173-1, EN50288-6-2, ISO/IEC11801, IEC61156-6 e IEEE802.3af/at/bt
2. Flame Retardant
UNE-EN 60332-1 (IEC 60332-1)
3. Halogen free
UNE-EN 60754 (IEC 60754)
4. Low smoke emission
UNE-EN 61034 (IEC 61034)
5. CPR Classification (Euroclass)
Eca
(According to UNE-EN 50575)