Cat 6 Cable Cervicom DATA UUTP LSHF CPR

Category 6 halogen free data transmission cable with tight design (AWG24) for Local Area Networks (LAN), Primary (Campus), Secondary (Riser), Tertiary (Horizontal). For Telephone Systems, Ethernet, Fast Ethernet and Gigabit Ethernet applications, 10BaseT, 100BaseT, 1000BaseT, 1GBase-T up to 1,000 Mbit/s. Suitable for PoE and PoE+ on a channel length of

See only CPR
See by cable type
See by fire behaviour

If you need technical support complete the form or call us at (+34) 937 362 730

Support
Cat. 6 - Cable Cervicom DATA U/UTP LSHF CPR
~\ImgCli\FOTO2_1292.jpg
Category 6 halogen free data transmission cable with tight design (AWG24) for Local Area Networks (LAN), Primary (Campus), Secondary (Riser), Tertiary (Horizontal). For Telephone Systems, Ethernet, Fast Ethernet and Gigabit Ethernet applications, 10BaseT, 100BaseT, 1000BaseT, 1GBase-T up to 1,000 Mbit/s. Suitable for PoE and PoE+ on a channel length of up to 100 m, TPDDI, ATM, CATV, IP cameras, broadband video, SOHO cabling.
Protegido electromagneticas
No propagador de la llama
Libre halogenos
Humos baja opacidad
Baka corrosividad gases
Construction
1. Conductor
Bare copper wire
Gauge: AWG24
2. Insulation
PE (Polyethylene)
Diameter: 1 mm Approx.
3. Composition
Twisted pairs laid up together with non-metallic cross separator
4. Outer sheath
Halogen free compound
Colour: Blue
Technical characteristics
1. Outer diameter
5,3 mm
2. Weight
38 Kg/Km
3. Operating Tª (conductor)
Fixed installation: -20°C to +60°C
During installation: 0°C to +50°C
4. Min. bending radius
Fixed installation: 4xD / During installation: 10xD
5. Loop resistance
190 Ohm/Km
6. Insulation resistance
5000 MOhm*Km
7. Mutual capacitance
Nominal 48 pF/m
8. Characteristic Impedance
100 Ohm Aprox.
9. Velocity of propagation
67%
10. Propagation delay
Nominal 535 ns/100m
11. Test Voltage
1000 V
12. Coupling attenuation
40 dB
13. Segregation class
b
Standards / Properties
1. Reference standards
EN50173-1; EN50288-6-1, ISO/IEC11801; IEC61156-5 e IEEE802.3af/at/bt.
2. CPR Classification (Euroclass)
Dca-s2,d2,a1 (Según norma UNE-EN 50575)
3. Flame Retardant
UNE-EN 603332-1 (IEC 60332-1)
4. Halogen free
UNE-EN 60754-1 (IEC 60754-1)
5. Low corrosivity
UNE-EN 60754-2 (IEC 60754-2) (pH >= 4,3 ; conductivity =< 10µS/mm)
6. Low smoke emission
UNE-EN 61034 (IEC 61034)