See only CPR See by cable type Power cablesCerviflex power cable RV-K 0.6/1 kV CPRCerviflam Power Cable RZ1-K (AS) 0,6/1 kV CPRCerviflam Power Cable RZ1-K (AS+) 0,6/1 kV CPR Control cablesControl Cable Cerviflex VV-F 500V CPRCable Cerviflex H05VV-F 300/500V CPR <HAR>Cerviflex VV-K 0,6/1 KV CPRWiring cable Cerviflex H07V-K CPRWiring cable Cerviflam H07Z1-K (AS) CPRCable Cerviflex YSLY-JZ/-OZ CPRCable Cerviflex YSLY-JB/-OB CPRCable Cerviflam HSLH -JZ/-OZ -JB/OBConnection Cable Cervicord H07V-R CPRCable Cerviflam Z1Z1-K 0,6/1kV CPRCable Cerviflam Z1Z1-F (AS) 300/500V CPR Armoured cablesArmoured cable Cerviflex VVFV-K 0,6/1 kV CPRCable armoured Cerviflex RVFV-K 0,6/1 kV CPRArmoured cable Cerviflex RVMV-K / RVMAV-K 0,6/1 kV CPRArmoured Cable CERVICORD VOVMV-R 300/500V FB RH CPRArmoured cable Cerviflex ROVMV-K 0,6/1 kV CPRArmoured cable Cerviflam RZ1MAZ1-K / RZ1MZ1-K 0,6/1 kV CPRArmoured cable Cerviflam ROZ1MZ1-K (AS) 300/500V RH CPR Armoured cable Cerviflam RZ1MZ1-K (AS) 0,6/1kV RH CPR Screened and shielded cablesScreened cable Cerviflex YSLCY-JZ/-OZ 300/500V CPRShielded Cable Cerviflam HSLCH -JZ/OZ -JB/OB 300/500VShielded Cable Cerviflex RC4V-K 300/500V CPRScreened Cable Cerviflex RC4V-K 1000V CPRScreened Cable Cervipar PAR POS 300/500V CPRShielded Cable Cervitronic LiYCY 250V CPRCable Shielded Cerviflex VC4V-K 300/500V CPRShielded Cable Cerviflex VC4V-K 0,6/1kV CPRScreened Cable Cerviflam RC4Z1-K 300/500V CPRShielded Cable Cerviflam RC4Z1-K 0,6/1 kV CPRShielded cable Cerviflam Z1C4Z1-K 300/500V CPRShielded cable Cerviflam Z1C4Z1-K 0,6/1 kV CPRShielded cable Cerviflam Z1C4Z1-K (AS) 300/500V CPRShielded cable Cerviflam Z1C4Z1-K (AS) 0,6/1kV CPRShielded Cable CERVIPAR POS 500V CPR Data cablesCable Cervitronic LiYY 250V CPRCat. 5e - Cable Cervicom DATA U/UTP PVC CPRCat. 5e - Cable Cervicom DATA U/UTP LSHF CPRCat. 5e - Cable Cervicom DATA U/UTP ARMOURED PE (Outdoors)Cat. 5e - Cable Cervicom DATA U/UTP LSHF PATCH (Flexible) CPRCat. 5e - Cable Cervicom DATA F/UTP PVC CPRCat. 5e - Cable Cervicom DATA F/UTP LSHF CPRCat. 5e - Cable Cervicom DATA F/UTP ARMOURED PE (Outdoors)Cat. 5e - Cable Cervicom DATA F/UTP LSHF PATCH (Flexible) CPRCat. 6 - Cable Cervicom DATA U/UTP PVC CPRCat. 6 - Cable Cervicom DATA U/UTP LSHF CPRCat. 6 - Cable Cervicom DATA U/UTP PVC PATCH (Flexible) CPRCat. 6 - Cable Cervicom DATA U/FTP PVC CPRCat. 6 - Cable Cervicom DATA U/FTP LSHF CPRCat. 6 - Cervicom DATA F/UTP ARMOURED PE (Outdoors)Cat. 6 - Cable Cervicom DATA S/FTP LSHF CPRCat. 6 - Cable Cervicom DATA U/FTP LSHF PATCH (Flexible) CPRCat. 6A - Cable Cervicom DATA U/UTP LSHF CPRCat. 6A - Cable Cervicom DATA U/UTP LSHF CPR-B2CaCat. 6A - Cable Cervicom DATA F/FTP LSHF CPRCat. 7 - Cable Cervicom DATA S/FTP LSHF CPRCat. 7A - Cable Cervicom DATA S/FTP LSHF CPR BUS cablesCable Cervicom BUS EIB-KNX CPRCable Cervicom BUS EIB-KNX LSHF CPR Rubber cablesCable Cerviflex DN-F 0,6/1kV CPRCable Cerviflex H07RN-F 450/750V CPRCable Cerviflex NSGAFOEU 1,8/3 kV CPRCable Cerviflam H07ZZ-F 450/750V CPR Fire & security cablesCable Cervicom Altavoz C/Funda CPRCable Cervicom Alarm Screened CPRCable Cervicom Alarm Screened HF CPRCable Cervifire (AS) POS 300/500V CPRCable Cervifire (AS+) SOZ1-K 300/500V CPR Telephonic cablesCable Cervicom Unshielded Interf LSHF CPRICT - Shielded Cervicom LSHF CPRCable Cervicom EAP Pairs Outdoor Telephone CPRCable Cervicom EAPSP Pairs Armoured Telephone CPRCable Cervicom Reinforced Drop CPRCable Cervicom Self-supported Drop Cable CPR Solar and renewable energy cablesElectrical Cable Cerviflam SOLAR TUV (H1Z2Z2-K) CPR Railway cablesCable Cervicom EAPSP Multicore 1,4mm CPRCable Cervicom EAPSP-R Multicore 1,4mm CPRCable Cervicom EAPSP Quads CPRCable Cervicom EAPSP-R Quads 0,9mm CPR Fiber optics cablesCable Cervicom FIBRE CERH CAHR LSHF CPRCable Cervicom FIBRE CERH DAHR LSHF CPR Coaxial cables RG MIL standardCable Cervicom Coaxial RG-214Cable Cervicom Coaxial RG-223 Coaxial antenna cablesCable COAX ANTENA TV-PLUS 5G HF WHITE CPRCable Cervicom COAX ANTENA TV-PLUS 5G PE BLACK CPRCable Cervicom COAX RG-6 ICT RBA-6 HF BLACK CPR Cables for variable frequency drives (VFD)Shielded cable Cerviwire NYCY 0,6/1 kV CPRShielded cable Cervicord NYCWY 0,6/1 kV CPRShielded cable Cerviflam N2XCH 0,6/1 kV CPRCable apantallado Cerviflam VFD 0,6/1kV Cabling systems and RacksCabling system UTP Cat.5eCabling system UTP Cat.6Cabling System UTP Cat.6ACabling System FTP Cat.6Cabling System FTP Cat.6A Intrinsic safety cablesIntrinsically Safe circuits cable Cerviflam EB RC4Z1-K 300/500V CPRIntrinsically Safe circuits cable Cerviflam EB Z1C4Z1-K 300/500V CPRIntrinsically Safe circuits cable Cerviflam EB Z1Z1-F 300/500VIntrinsically Safe circuits cable Cerviflam EB RZ1-K 0,6/1kV CPRIntrinsically Safe circuits cable Cerviflam EB Z1Z1-K 0,6/1kV CPR See by fire behaviour PVC and rubber cables Halogen-free cables Fire resistant cables If you need technical support complete the form or call us at (+34) 937 362 730 Support Cat. 6 - Cable Cervicom DATA U/UTP PVC PATCH (Flexible) CPR Flexible cable for Category 6 data transmission in local area networks (LAN), suitable for the work area (computers) and panel wiring. Cat. 6 - Cable Cervicom DATA U/UTP PVC PATCH (Flexible) CPR Construction1. ConductorStranded tinned copper wires Diameter: 0,51 mm (AWG26/7)2. InsulationPolyethylene Diameter: 0,98 mm3. CompositionTwo insulated conductors twisted together as a pair4. Pair Screen-5. Assembly4 twisted pairs laid up together6. Overall screen-7. Outer sheathPVC Colour: GreyTechnical characteristics1. Outer diameter5,5 mm2. Weight34 Kg/Km3. Operating TªFixed installation: -20°C to +60°C / During installation: 0°C to +50°C4. Min. bending radiusFixed installation (without load): 25mm / During installation (with load): 50mm5. Loop resistance195 Ohm/Km Max.6. Resistance unbalance2% Max.7. Insulation resistance5000 MOhm*Km Min. (500V)8. Mutual capacitanceNominal 52 pF/m (at 800Hz)9. Capacitance unbalance1500 pF/Km Max. (Pair-Ground)10. Characteristic Impedance100 ± 5 Ohm (at 100 MHz)11. Velocity of propagation67%12. Propagation delayNominal 520 ns/100m13. Test Voltage1000 V (DC, 1 min)14. Transfer Impedance- 15. Coupling attenuation40 dB Min.16. Segregation class-Standards / Properties1. Ref. standard for drawingTIA/EIA 568B; ISO/IEC 11801 Ed.2; IEC 61156-6; EN 50173; EN 50288-6-22. Flame RetardantUNE-EN 60332-1 (IEC 60332-1)3. CPR Classification (Euroclass)Eca (According to UNE-EN 50575)
See only CPR See by cable type Power cablesCerviflex power cable RV-K 0.6/1 kV CPRCerviflam Power Cable RZ1-K (AS) 0,6/1 kV CPRCerviflam Power Cable RZ1-K (AS+) 0,6/1 kV CPR Control cablesControl Cable Cerviflex VV-F 500V CPRCable Cerviflex H05VV-F 300/500V CPR <HAR>Cerviflex VV-K 0,6/1 KV CPRWiring cable Cerviflex H07V-K CPRWiring cable Cerviflam H07Z1-K (AS) CPRCable Cerviflex YSLY-JZ/-OZ CPRCable Cerviflex YSLY-JB/-OB CPRCable Cerviflam HSLH -JZ/-OZ -JB/OBConnection Cable Cervicord H07V-R CPRCable Cerviflam Z1Z1-K 0,6/1kV CPRCable Cerviflam Z1Z1-F (AS) 300/500V CPR Armoured cablesArmoured cable Cerviflex VVFV-K 0,6/1 kV CPRCable armoured Cerviflex RVFV-K 0,6/1 kV CPRArmoured cable Cerviflex RVMV-K / RVMAV-K 0,6/1 kV CPRArmoured Cable CERVICORD VOVMV-R 300/500V FB RH CPRArmoured cable Cerviflex ROVMV-K 0,6/1 kV CPRArmoured cable Cerviflam RZ1MAZ1-K / RZ1MZ1-K 0,6/1 kV CPRArmoured cable Cerviflam ROZ1MZ1-K (AS) 300/500V RH CPR Armoured cable Cerviflam RZ1MZ1-K (AS) 0,6/1kV RH CPR Screened and shielded cablesScreened cable Cerviflex YSLCY-JZ/-OZ 300/500V CPRShielded Cable Cerviflam HSLCH -JZ/OZ -JB/OB 300/500VShielded Cable Cerviflex RC4V-K 300/500V CPRScreened Cable Cerviflex RC4V-K 1000V CPRScreened Cable Cervipar PAR POS 300/500V CPRShielded Cable Cervitronic LiYCY 250V CPRCable Shielded Cerviflex VC4V-K 300/500V CPRShielded Cable Cerviflex VC4V-K 0,6/1kV CPRScreened Cable Cerviflam RC4Z1-K 300/500V CPRShielded Cable Cerviflam RC4Z1-K 0,6/1 kV CPRShielded cable Cerviflam Z1C4Z1-K 300/500V CPRShielded cable Cerviflam Z1C4Z1-K 0,6/1 kV CPRShielded cable Cerviflam Z1C4Z1-K (AS) 300/500V CPRShielded cable Cerviflam Z1C4Z1-K (AS) 0,6/1kV CPRShielded Cable CERVIPAR POS 500V CPR Data cablesCable Cervitronic LiYY 250V CPRCat. 5e - Cable Cervicom DATA U/UTP PVC CPRCat. 5e - Cable Cervicom DATA U/UTP LSHF CPRCat. 5e - Cable Cervicom DATA U/UTP ARMOURED PE (Outdoors)Cat. 5e - Cable Cervicom DATA U/UTP LSHF PATCH (Flexible) CPRCat. 5e - Cable Cervicom DATA F/UTP PVC CPRCat. 5e - Cable Cervicom DATA F/UTP LSHF CPRCat. 5e - Cable Cervicom DATA F/UTP ARMOURED PE (Outdoors)Cat. 5e - Cable Cervicom DATA F/UTP LSHF PATCH (Flexible) CPRCat. 6 - Cable Cervicom DATA U/UTP PVC CPRCat. 6 - Cable Cervicom DATA U/UTP LSHF CPRCat. 6 - Cable Cervicom DATA U/UTP PVC PATCH (Flexible) CPRCat. 6 - Cable Cervicom DATA U/FTP PVC CPRCat. 6 - Cable Cervicom DATA U/FTP LSHF CPRCat. 6 - Cervicom DATA F/UTP ARMOURED PE (Outdoors)Cat. 6 - Cable Cervicom DATA S/FTP LSHF CPRCat. 6 - Cable Cervicom DATA U/FTP LSHF PATCH (Flexible) CPRCat. 6A - Cable Cervicom DATA U/UTP LSHF CPRCat. 6A - Cable Cervicom DATA U/UTP LSHF CPR-B2CaCat. 6A - Cable Cervicom DATA F/FTP LSHF CPRCat. 7 - Cable Cervicom DATA S/FTP LSHF CPRCat. 7A - Cable Cervicom DATA S/FTP LSHF CPR BUS cablesCable Cervicom BUS EIB-KNX CPRCable Cervicom BUS EIB-KNX LSHF CPR Rubber cablesCable Cerviflex DN-F 0,6/1kV CPRCable Cerviflex H07RN-F 450/750V CPRCable Cerviflex NSGAFOEU 1,8/3 kV CPRCable Cerviflam H07ZZ-F 450/750V CPR Fire & security cablesCable Cervicom Altavoz C/Funda CPRCable Cervicom Alarm Screened CPRCable Cervicom Alarm Screened HF CPRCable Cervifire (AS) POS 300/500V CPRCable Cervifire (AS+) SOZ1-K 300/500V CPR Telephonic cablesCable Cervicom Unshielded Interf LSHF CPRICT - Shielded Cervicom LSHF CPRCable Cervicom EAP Pairs Outdoor Telephone CPRCable Cervicom EAPSP Pairs Armoured Telephone CPRCable Cervicom Reinforced Drop CPRCable Cervicom Self-supported Drop Cable CPR Solar and renewable energy cablesElectrical Cable Cerviflam SOLAR TUV (H1Z2Z2-K) CPR Railway cablesCable Cervicom EAPSP Multicore 1,4mm CPRCable Cervicom EAPSP-R Multicore 1,4mm CPRCable Cervicom EAPSP Quads CPRCable Cervicom EAPSP-R Quads 0,9mm CPR Fiber optics cablesCable Cervicom FIBRE CERH CAHR LSHF CPRCable Cervicom FIBRE CERH DAHR LSHF CPR Coaxial cables RG MIL standardCable Cervicom Coaxial RG-214Cable Cervicom Coaxial RG-223 Coaxial antenna cablesCable COAX ANTENA TV-PLUS 5G HF WHITE CPRCable Cervicom COAX ANTENA TV-PLUS 5G PE BLACK CPRCable Cervicom COAX RG-6 ICT RBA-6 HF BLACK CPR Cables for variable frequency drives (VFD)Shielded cable Cerviwire NYCY 0,6/1 kV CPRShielded cable Cervicord NYCWY 0,6/1 kV CPRShielded cable Cerviflam N2XCH 0,6/1 kV CPRCable apantallado Cerviflam VFD 0,6/1kV Cabling systems and RacksCabling system UTP Cat.5eCabling system UTP Cat.6Cabling System UTP Cat.6ACabling System FTP Cat.6Cabling System FTP Cat.6A Intrinsic safety cablesIntrinsically Safe circuits cable Cerviflam EB RC4Z1-K 300/500V CPRIntrinsically Safe circuits cable Cerviflam EB Z1C4Z1-K 300/500V CPRIntrinsically Safe circuits cable Cerviflam EB Z1Z1-F 300/500VIntrinsically Safe circuits cable Cerviflam EB RZ1-K 0,6/1kV CPRIntrinsically Safe circuits cable Cerviflam EB Z1Z1-K 0,6/1kV CPR See by fire behaviour PVC and rubber cables Halogen-free cables Fire resistant cables If you need technical support complete the form or call us at (+34) 937 362 730 Support
Flexible cable for Category 6 data transmission in local area networks (LAN), suitable for the work area (computers) and panel wiring. Cat. 6 - Cable Cervicom DATA U/UTP PVC PATCH (Flexible) CPR Construction1. ConductorStranded tinned copper wires Diameter: 0,51 mm (AWG26/7)2. InsulationPolyethylene Diameter: 0,98 mm3. CompositionTwo insulated conductors twisted together as a pair4. Pair Screen-5. Assembly4 twisted pairs laid up together6. Overall screen-7. Outer sheathPVC Colour: GreyTechnical characteristics1. Outer diameter5,5 mm2. Weight34 Kg/Km3. Operating TªFixed installation: -20°C to +60°C / During installation: 0°C to +50°C4. Min. bending radiusFixed installation (without load): 25mm / During installation (with load): 50mm5. Loop resistance195 Ohm/Km Max.6. Resistance unbalance2% Max.7. Insulation resistance5000 MOhm*Km Min. (500V)8. Mutual capacitanceNominal 52 pF/m (at 800Hz)9. Capacitance unbalance1500 pF/Km Max. (Pair-Ground)10. Characteristic Impedance100 ± 5 Ohm (at 100 MHz)11. Velocity of propagation67%12. Propagation delayNominal 520 ns/100m13. Test Voltage1000 V (DC, 1 min)14. Transfer Impedance- 15. Coupling attenuation40 dB Min.16. Segregation class-Standards / Properties1. Ref. standard for drawingTIA/EIA 568B; ISO/IEC 11801 Ed.2; IEC 61156-6; EN 50173; EN 50288-6-22. Flame RetardantUNE-EN 60332-1 (IEC 60332-1)3. CPR Classification (Euroclass)Eca (According to UNE-EN 50575)
Power cablesControl cablesArmoured cablesScreened and shielded cablesData cablesCrain, conveyor and lift cablesDrag chain cablesServo, encoder and motor cablesBUS cablesRubber cablesFire & security cablesCabling systems and Racks High temperature cablesTelephonic cablesSolar and renewable energy cablesRailway cablesMarine cablesFiber optics cablesCoaxial cables RG MIL standardCoaxial antenna cablesElectrical Company CablesCables for variable frequency drives (VFD)Thermocouple cablesIntrinsic safety cables Libra, 61 (Pl. Can Parellada) • 08228 Terrassa, Barcelona (SPAIN) +34 93 736 27 30 Comercial: cervi@cervi.es Partners